Skip to main content
 

FDE Series

The FDE series of ceiling suspended systems offer a versatile solution for commercial spaces with limited floor or ceiling space such as restaurants, cafes and retail spaces.

With a reduction in weight and improved component design, the FDE series boasts easier installation, higher energy efficiency and quieter operation.


POWER: Single Phase & Three Phase | AVAILABLE IN: Reverse Cycle

CAPACITIES: 7.1kW | 10.0kW | 12.1kW | 12.5kW | 14.0kW

Key features

  • Quiet operation
  • Various timer functions for convenience
  • High Power mode for rapid cooling/heating

SELECT A CAPACITY TO VIEW SPECIFICATIONS

Single Phase
THREE PHASE
Specifications
SELECTED MODEL: SRK20ZSA-W / DXK06ZSA-W
Capacity
COOLING:
HEATING:
Energy Labels
Hot
COOLING:
HEATING:
Average
COOLING:
HEATING:
Cold
COOLING:
HEATING:
Dimensions (HxWxD)
INDOOR:
OUTDOOR:
Energy Saving
Home Leave Operation

Maintains a moderate indoor temperature, avoiding extremely hot or cool temperatures. Suitable for when rooms are unoccupied for long periods of time.

Set Temperature Auto Return

Program a preferred set temperature that the unit will return to each time it is switched on. Requires RC-EXZ3A wired controller.

Comfort & Convenience
Automatic Operation

Automatically selects the required heating or cooling function based on the current room conditions and set temperature.

Function Switch

Set two functions to operate automatically. Requires RC-EXZ3A wired controller and no other central controller to be connected.

Peak-Cut Timer

Set the capacity limit during peak billing times, minimising energy consumption and reducing running costs. Requires RC-EXZ3A wired controller.

Hi Power Operation

Provides 15mins of boosted power to quickly heat or cool your home before returning to normal operation. Perfect for when you first turn on it the unit.

Silent Operation

Set periods of time where the unit will operate with reduced noise levels, perfect for night time and an uninterrupted sleep.

Weekly Timer

Set your unit to turn on and off at specific times for each day of the week to suit your needs.

Sleep Timer

Set a pre-determined amount of time between 30 and 240 mins that your unit will operate for before switching off.

Air Flow
Louvre Control System

Set the upper and lower limit positions of each individual louvre, providing you with complete control over internal airflow.

Vertical Auto Swing

The vertical louvres on your unit will move up and down continuously during operation. This function allows you to set the up/down swing position of the louver to your preferred operation angle.

Air Filter

Traps and removes air borne dust particles and other allergens, providing you with clean air throughout your home.

Filter Sign

Alerts you to when the filter needs to be cleaned.

Automatic Fan Speed

The unit’s on-board microcomputer continuously monitors the room’s air temperature and adjusts the fan speed accordingly.

Maintenance
Self-Diagnostics

In the unlikely event of a fault the internal microcomputer automatically runs a diagnostic of the system. This enables a service agent to quickly isolate and repair any issues.

SELECT CONTROLLER TYPE FOR DETAILS:
RC-EXZ3A
RCN-E-E2
RC-E5
RCH-E3
Wi-Fi
High Power Mode
Provides 15mins of boosted power allowing you to quickly heat or cool your home.
Silent Operation
Set periods of time where the unit will operate with even further reduced noise levels.
Individual Louvre Control
Set the upper and lower limit positions of the louvre at each air outlet individually.
Sleep Timer
Set a pre-determined amount of time that your unit will operate for before switching off.
Weekly Timer
Set your unit to turn on and off up to 4 times each day of the week.
Peak Cut Timer
Set capacity limit of the system, minimising energy consumption during peak billing times.

Download Manual
High Power Mode
Provides 15mins of boosted power allowing you to quickly heat or cool your home.
Night Setback
Maintains room temperature during cold conditions, even when the room is unattended.
Economy Mode
Reduces power consumption while maintaining a comfortable room temperature.
On/Off Timer
Set your unit to turn on and off once within a 24 hour period.
Child Lock
Disables the controller and prevents inadvertent changes to the control settings.
Night Setback
Maintains room temperature during cold conditions, even when the room is unattended.

For more information on the functions available and how to access them on your remote control, please refer to your unit’s user manual.

Download Manual

  • Enables extensive access to service and maintenance technical data combined with easy to use functions and a clear LCD display.
  • Weekly Timer function is a standard inclusion. This allows users to set up to 28 different timers, on and off operations, in a week with 4 timer programs per day available.
  • The temperature of the room is controlled by the remote control sensor.
  • Easily enable silent operation which allows you to program periods of operation at lower noise levels, ideal for temperature control during the night.
    The Filter Sign warning alerts you to when the filter needs to be cleaned.
  • The LCD display allows you to see errors that may occur in your heat pump system. The heat pump will stop in the event that any trouble occurs. At the same time, the check indicator light flashes in red and the error code will be displayed in the ON timer display area.

 

Download Manual

 

  • With the ability to control up to 16 indoor units, RCH-E3 is intended for use in a setting where everyday users only need access to the basic functions.
  • With the RCH-E3 users can turn the heat pump ON/OFF and control the mode, temperature and fan speed settings.

 

Note: Simple remote control is not applicable to the individual flap control system nor Draught Control Technology. When this remote is used the fan has 3 speed settings (Hi-Me-Lo) only.

 

 

 

 

 

Download Manual

Control your system using your smart device (iPhone, iPad) or internet browser via to easy to use AC Cloud Control app*.

  • Control the set temperature, operation mode and fan speed.
  • Control your system via your Google or Amazon smart speaker device.
  • Control your system using Voice Commands.
  • Set up ‘favourite’ scenes and activate them with a single tap.
  • Set your system to respond to the weather, you arriving home, calendar events + more**.
  • Receive instant notifications and email updates and create usage logs**.

*Wi-Fi control requires MH-RC-WIFI-1B Wi-Fi adaptor (sold separately)
**In conjunction with IFTTT and other apps (must be downloaded separately).

Note: Some functions for some heat pumps may not be available via AC Cloud Control app. On/Off timer, weekly timer and sleep timer are disabled if Wi-Fi accessory connected. Similar functions can be set via the AC Cloud application.

Download Manual
FDE Series
Ceiling Systems Brochure
FDE Series
User Manual RC-EXZ3A Controller (FDCA, FDUA, FDUM, FDT, FDTC, FDE Series)
FDE Series
User Manual FDE-VG Wireless Control (RCN-E-E2)
FDE Series
User Manual RC-E5 Controller (FDCA, FDUA, FDUM, FDT, FDTC, FDE Series)
FDE Series
User Manual RCH-E3 Controller (FDUA, FDUM, FDCA, FDT, FDTC, FDE Series)
FDE Series
User Manual Wi-Fi Control (MH-RC-WIFI-1B) FDCA, FDUA, FDUM, FDT, FDTC, FDE SERIES

Why Mitsubishi Heavy Industries?

Consumer people's choice logo for mitsubishi heavy industries - best brand of heat pumps for split system

New Zealand's Best Brand
of Heat Pump

We're proud to have been named by Consumer, New Zealand's leading customer advocacy group, as The People’s Choice of heat pumps.

Reliability

Designed to perform in the most demanding environments on earth, we engineer our products to endure its harshest conditions.

Superior Technology

With world-class engineering and product innovation in our DNA, we push the boundaries to develop technology that ensures your comfort year after year.

Commitment to Our Customers

Standing behind the quality of our products is our commitment to our customers and after sales service guarantees with comprehensive warranties providing you peace of mind.
TECHNICAL SPECIFICATIONS
ABCDEFGHIJKLMNO
1
SetFDE71AVNXWVHFDE100AVNAWVHFDE100AVNPWVHFDE125VNPWVHFDE125AVNPWVHFDE125AVNXWVHFDE140AVNXWVHFDE100AVSAWVHFDE125AVSXWVHFDE140AVSXWVH
2
IndoorFDE71VHFDE100VHFDE100VHFDE125VHFDE125VHFDE125VHFDE140VHFDE100VHFDE125VHFDE140VH
3
OutdoorFDCA71VNX-WFDCA100VNA-WFDCA100VNP-WFDC125VNP-WFDCA125VNP-WFDCA125VNX-WFDCA140VNX-WFDCA100VSA-WFDCA125VSX-WFDCA140VSX-W
4
Power source (Outdoor Unit)1 Phase 240V 50Hz3 Phase 380-415V 50Hz
5
*Operation dataNominal Capacity (Range)Cooling T1kW7.1 (3.2-8.0)10.0 (4.0-11.2)10 (2.1 -10.2)12.1 (5.0-12.1)12.1 (5.0-12.1)12.5 (3.5-14.0)14.0 (3.5-16.0)10.0 (4.0-11.2)12.5 (3.5-14.0)14.0 (3.5-16.0)
6
Heating H18.0 (3.6-9.0)11.2 (4.0-12.5)10 (1.7 - 10.4)12.1 (4.0-13.3)12.1 (4.0-13.3)14.0 (2.7-17.0)16.0 (2.7-18.0)11.2 (4.0-12.5)14.0 (2.7-18.0)16.0 (2.7-20.0)
7
Heating H27.4107.67.97.914.915.51014.915.5
8
Power consumptionCooling T1kW1.872.8533.883.883.344.082.853.774.08
9
Heating H11.872.542.363.33.33.744.412.543.744.41
10
Maximum power consumptionkW4.116.44.464.754.757.17.110.28.98.9
11
Running currentCooling T1A8.313.812.816.316.314.717.94.66.36.5
12
Heating H18.312.410.113.913.916.419.446.37.2
13
Inrush current, maximum currentA5, 19.15, 245, 195, 185, 185, 275, 275, 155, 145, 14
14
EERCooling T13.83.513.333.123.123.753.433.513.753.43
15
COPHeating H14.284.414.243.673.673.743.634.413.743.63
16
Sound power level (JIS C9612)OutdoordB(A)66706873736869696869
17
Sound pressure level (JIS C9612)IndoordB (A)P-Hi:47 Hi:41 Me:37 Lo:32P-Hi:48 Hi:43 Me:38 Lo:34P-Hi: 48 Hi: 43 Me: 38 Lo: 34P-Hi: 48 Hi: 45 Me: 40 Lo: 35P-Hi: 48 Hi: 45 Me: 40 Lo: 35P-Hi:48 Hi:45 Me:40 Lo:35P-Hi:49 Hi:45 Me:40 Lo:36P-Hi:48 Hi:43 Me:38 Lo:34P-Hi:48 Hi:45 Me:40 Lo:35P-Hi:49 Hi:45 Me:40 Lo:36
18
Outdoor51555657575454555454
19
External dimensions (HxWxD)Indoormm210x1320x690250x1620x690250x1620x690250x1620x690250x1620x690250x1620x690250x1620x690250x1620x690250x1620x690250x1620x690
20
Outdoor750x880(+88)x340845×970×370750 × 880(+88) × 340845x970x370845x970x3701300x970x3701300x970x370845×970×3701300x970x3701300x970x370
21
Net weightIndoorkg33434343434343434343
22
Outdoor60775773739797789999
23
AirflowIndoor (Cooling)l/sP-Hi:333 Hi:267 Me:217 Lo:167P-Hi:533 Hi:433 Me: 350 Lo: 275P-Hi:533 Hi:433 Me:350 Lo:275P-Hi:533 Hi:483 Me: 383 Lo: 283P-Hi:533 Hi:483 Me: 383 Lo: 283P-Hi:533 Hi:483 Me: 383 Lo: 283P-Hi:567 Hi:483 Me: 383 Lo: 300P-Hi:533 Hi:433 Me: 350 Lo: 275P-Hi:533 Hi:483 Me: 383 Lo: 283P-Hi:567 Hi:483 Me: 383 Lo: 300
24
Indoor (Heating)
25
Refrigerant (R32)Quantitykg2.753.31.72.252.25443.344
26
Pre charged to pipe lengthm30301515153030303030
27
Installation dataRefrigerant pipingLiquid linemmØ9.52Ø9.52Ø6.35**Ø9.52Ø9.52Ø9.52Ø9.52Ø9.52Ø9.52Ø9.52
28
Gas lineØ15.88Ø15.88Ø15.88Ø15.88Ø15.88Ø15.88Ø15.88Ø15.88Ø15.88Ø15.88
29
Connection methodFlare ConnectionFlare Connection
30
Maximum pipe (one way) lengthm505030303010010050100100
31
Max vertical height diff. between O.U. and I.U.m30 ( O.U. above I.U. ) / 15 ( O.U. below I.U. )50 ( O.U. above I.U. ) / 15 ( O.U. below I.U. )20 ( O.U. above I.U. ) / 20 ( O.U. below I.U. )20 ( O.U. above I.U. ) / 20 ( O.U. below I.U. )50 ( O.U. above I.U. ) / 15 ( O.U. below I.U. )50 ( O.U. above I.U. ) / 15 ( O.U. below I.U. )50 ( O.U. above I.U. ) / 15 ( O.U. below I.U. )50 ( O.U. above I.U. ) / 15 ( O.U. below I.U. )50 ( O.U. above I.U. ) / 15 ( O.U. below I.U. )
32
ControllerRC-E5, RC-EXZ3A, RCH-E3 or RCN-E-E3RC-E5, RC-EXZ3A, RCH-E3 or RCN-E-E3
33
Motion Sensor (Optional)LB-ELB-E
34
Demand response (AS4755)YesYesYesNoYesYesYesYesYesYes
35
Outdoor air temperature (upper, lower limits)CoolingC-15 to 50-15 to 50-15 to 46-15 to 46-15 to 46-15 to 50-15 to 50-15 to 50-15 to 50-15 to 50
36
HeatingC-20 to 20-20 to 20-15 to 20-15 to 20-15 to 20-20 to 20-20 to 20-20 to 20-20 to 20-20 to 20
37
* Operation data has been gathered in accordance with AS/NZS 3823 standards.
38
**Reducer set Ø9.52 -> Ø6.35 is included in the outdoor unit as accessory for FDCA100VNP-W.

Request a Quote

Leave some details and we'll get an installer to get in touch!